Tuesday, March 13, 2012

Site Description

Introduction
Research each of the following for your site. In most cases a potential source of information is given; however, you may need to find additional sources of information in order to gather sufficient data. The websites in brackets [ ] indicate possible sources of information specific to the Palmetto Property. Cop and paste into your blog with the title "Site Description."
1.     Plat – Recorder of Deeds or Public Records Online Directory website
2.     Tax map - Recorder of Deeds or Public Records Online Directory website
3.     Topographic map (free USGS topo Maps via Map Locator at http://store.usgs.gov/)
4.     Soils map and soil characteristics data, soil boring data (if available)
5.     Web Soil Survey (WSS) at http://websoilsurvey.nrcs.usda.gov/  
6.     Building Code
2008 Indiana Building Code (2006 IBC with state amendments) & 2005 Indiana Residential Code (2003 IRC) with amendments
7.     Municipal Ordinances (Online Library at http://www.municode.com/ or library at http://www.amlegal.com
8.     Zoning Map (municipal ordinances or online map)
Lancaster
9. Flood Insurance Rate Map (create a FIRMette on the FEMA Map Service website at http://msc.fema.gov)
Not a flood zone
10. Wetlands Inventory (National Wetlands Inventory at http://www.fws.gov/wetlands/Data/Mapper.html)
Freshwater Emergent ground, Riverine Pond
11. Coastal Zone regulations if applicable (http://coastalmanagement.noaa.gov/mystate/welcome.html)
Not necessary 
12. Endangered Species Critical Habitat Map (FWS Critical Habitat Portal at http://criticalhabitat.fws.gov/)
Indian Bat Myoto Sodalis = Endangered
Bald Eagle Recovery Programs
13. Superfund sites (EPA National Priorities List webpage at http://www.epa.gov/superfund/sites/npl/index.htm)
There are no hazardous materials on the loose around the proposed construction site.
14. Public Transportation Routes nearby
Railway Line; Highway U.S. 224; State Road 1, 2 miles East
15. Local emergency medical, police, and fire stations
Sheriff Department in Bluffton, w/police station
Police Station in Ossian
Fire Stations in Ossian and Bluffton
One Hospital in Bluffton

Wednesday, January 11, 2012

Monday, January 9, 2012

Introduction

Larger commercial buildings often employ low-slope (almost flat) roofs. The low slope of the roof allows the roof to be used to support equipment and may also provide an area for human use. Recently “green roofs” on which plants are grown have become popular. In this activity you will discover what accommodations are necessary in order to make a low-slope roof acceptable for human traffic and for use as a green roof.


Procedure

1.    Select a low slope roof treatment for the upper roof of the Keystone project and incorporate your choice into your 3D architectural model.  Do not include structural support of the roof at this time.

2.    Research low-slope roof treatments and walking surfaces that would allow human traffic. In your engineering notebook document three products that could be used as a walking surface on the green roof planned for the lower roof of the Keystone Library. Include sketches or images of each product. Show it to Mr. Torwelle before you move on.

3.    Research green roofs and document at least two green roof systems that could be used on the lower roof of the Keystone Library. Select a green roof system for use on the Keystone Library Renovation. In your engineering notebook document your selection with a sketch or image of a cross section or of the selected system and label each required layer. Justify your choice. Show it to Mr. Torwelle before you move on.

4.    Model the green roof system in your 3D architectural software. Do not include structural support of the roof at this time.

5.    Create a detail (section) view of the green roof in your 3D architectural software.

Conclusion Questions to answer in your blog.
1.    Why are flat roofs common on larger commercial buildings?
They are more practical compared to peaked roofs because commercial buildings can be very large. They can be also be built very quickly and easily.

2.    Why are the standard pitched roof treatments not acceptable for a low-slope roof?
The low slope roof needs different drains to direct the water away from the building and need more water proofing because of their low slope.

3.    Why are the typical low-slope roof surfaces not appropriate when public access is planned?
Some low slope roofs have a coating that may not be appropriate for walking on, such as foam.


4.     What factors are important to consider when designing a green roof?
The weight of all of the soil on the roof, water proofing so the moisture in the soil doesn't go into the building, maintenance of the plants and the roof itself, and the plants you want to put on the roof.

5.    What advantages do green roofs provide over standard low-slope roof treatments?
They are more aesthetically pleasing and eco friendly 

Monday, December 12, 2011

Activity 3.1.2

Introduction
Most locations within the United States fall within a municipality that regulates land use within its jurisdiction. Land Use regulations are designed to protect and promote the public health, safety, and general welfare. Typically they include Zoning Ordinances that control development by designating areas for specific types of use. These ordinances include laws that control a wide variety of development activities within each zoning area, including building construction, parking lot design, entrances and exits from property, water and sewer facilities, storm water runoff, and landscaping.


As part of local Land Use regulations, many municipalities have adopted the International Building Code to regulate the design and construction of non-residential buildings. Although some jurisdictions within a state may not use the IBC, state or local regulations will typically adopt the IBC by reference, meaning that the requirements of the IBC apply within the jurisdiction of that state or other government body.


Rules that control other aspects of development vary and are published by each municipality. It is important to identify the codes and regulations that apply to a project and become familiar with the requirements for development before beginning the design of a project.


Equipment
· Keystone Library Site Location Map
· Keystone Library Site Plan
· City of Noblesville, Indiana Code of Ordinances (found at http://www.amlegal.com/library/)
o Section 154.04 Adoption of Rules by Reference
o Section 159.105 Zoning Districts General Requirements
o Section 159.107 Commercial Districts
o Section 159.120 General Regulations
o Appendix C
· International Building Code 2009
o Section 302
o Section 303
o Section 503
o Section 602
o Section 1004
o Section 1005
o Section 1021
· Noblesville Zoning Map


Procedure
In this activity you will research the local code of ordinances and building codes to obtain important information needed to redesign the Keystone building.


The Keystone Building is within the city of Noblesville, Indiana. The Noblesville Code of Ordinances applies to this project location.


1. Identify the Building Code that applies in Noblesville by reviewing Section 154.04 Adoption of Rules by Reference in the Noblesville Code of Ordinances.
Indiana building code
2. Visit the Indiana Association of Building Officials website at http://www.iabo.com/ and follow the link to Current Codes. On which model code is the current Indiana Building Code based?
International Building Code
3. Using the International Building Code, find the Use and Occupancy classification of the proposed new Keystone Building.
Low-hazard storage, Group S-2 
4. Using the International Building Code, describe each of the four types of construction. Based on the existing structure, under which of these types of construction could the Keystone Building fall? See section 503.1.
I. Steele framing encased in concrete
II. Steele framing
III. Noncombustable exterior, treated wood interior 
IV.Heavy timber
V. Any materials allowed by code
Type IV
5. Compare the allowable Building Heights and Areas (IBC 2009 Table 503) for the Keystone Library using different construction types. What is the least restrictive construction type that can be used for the Keystone Library? Is a fire-protective layer required over the structural elements? Note: The letter A indicates that the structural members are protected by a fire-rated coating or cover (sheetrock, spray on, or another approved method). The letter B indicates that the structural members are not protected by an additional fire-rated coating or cover.
A-3
6. What materials do you propose to use for the new interior walls and floor for the Keystone Building? Justify your answer.
Treated wood interior becuase you don't want the building with people in it to burn down quickly.
7. Use the IBC to determine the Occupant Load (IBC 2009 Section 1004) for the Keystone Building assuming a second floor is added. For now, conservatively assume that the second floor is entirely stacks and that the first floor is entirely reading rooms. In addition, because there is currently no plan to include an outside stairway to the roof, assume that the occupants of the green roof must exit through the 2nd floor. The building inspector has determined, based on the planned use of the green roof as additional reading area, that the occupant load for the green roof may be based on the requirements for reading rooms.
200
8. The occupant load is used to determine the minimum egress width for the building. Use the IBC to determine the required total egress width (IBC 2009 Section 1005) for the Keystone Building including the second floor.
60 cm
9. What is the minimum number of exits required for the Occupant Load (IBC 2009 Section 1021)?
Six exits
10. Read IBC 2009 Section 1021.2. Is it permissible to have only a single exit from the ground floor? From the second floor? Justify your answers.
No, becuase you need a minimum of two exits per floor.
The answers to the following questions should be researched in the Noblesville Code of Ordinances and the Noblesville Zoning Map.


11. In which zoning designation does the Keystone building property lie? (Refer to the Keystone Library Site Location Map to help locate the site on the zoning map.)

12. Describe the purpose of this zoning designation. Document your answer with a section number from the code.
13. What is the minimum lot size within this designation? Does the Keystone Property meet this requirement? Document your answer with a section number of the code.
14. What is the maximum building height according to the Noblesville ordinance?
15. Read Section 159.120 of the Noblesville Code of Ordinances. Record any information that is important to the redevelopment of the Keystone building.
16. Is the Use proposed in Keystone Building Project permitted on this property? Document your answer.
17. When developing a property, when is landscaping and screening required?